Product Information
MikroTest Magnetic Coating Thickness Gauges
Made in GERMANY
Application:
The MikroTest is the most widely used coating thickness gauge in the world over the last 40 years. The MikroTest complies with the highest technical standards of all analogue magnetic coating thickness gauges. This magnetic coating thickness gauge works on the magnetic attraction principle to measure all non-magnetic coatings on steel and galvanic nickel on steel.
The MikroTest is supplied in 11 different models to be suitable for every requested application. The balanced measuring system ensures accurate readings at any angle: horizontal, vertical and overhead. Also, the gauge allows measurements on curved surfaces. It is also able to provide you with precise measurements in tubes and on round parts due to the automatic operation.
The measurement of the coating thickness is based on magnetic attraction. The attractive force is related to the distance between a permanent magnet and a steel substrate. This distance represents the thickness of the coating under measure. The magnet is lifted from the surface by means of a spring connected to the magnet arm. The force needed to lift the magnet is directly related to the angle of rotation of the torsion spring. This measuring principle is also especially suited for electroplated nickel on copper, aluminum and other non-ferrous metals. This measurement principle ensures fully automatic measurement where no power supply or calibration is required.
Features:
Mils Models Include a NIST traceable calibration certificate, Micron Models include factory "works" certificate
Highest accuracy with simplest operation
No calibration required
Simple set-up and measurement
All gauges operate without power or battery
One point measurement
Metal Housing provides protection from mechanical shocks
Metal Housing and measuring system is resistant to solvents
Automatic models control realease of magnet for highest accuracy and repeatability
Specifications:
Type |
Range |
Typical Application |
Tolerance |
Min Surface |
Min Radius |
Min Base Thickness |
GM |
4mils |
Electroplating and Paint on Steel |
±1μm or 5% of reading |
Ø20mm |
5 mm convex/ 25mm concave |
0.5mm |
FM |
40mils |
Paint On Steel |
±5μm or 5% of reading |
Ø30mm |
mm convex/ 25mm concave |
0.5mm |
S3M |
8-120mils |
Enamel, Paint on Steel |
5% of reading |
Ø30mm |
15 mm convex/ 25mm concave |
1.0mm |
S5M |
20-200mils |
Enamel, Paint on Steel |
5% of reading |
Ø50mm |
15 mm convex/ 25mm concave |
1.0mm |
S10M |
0.1-0.4inches |
Enamel, Paint on Steel |
5% of reading |
Ø50mm |
15 mm convex/ 25mm concave |
2.0mm |
S20M |
0.3-0.8inches |
Enamel, Paint on Steel |
5% of reading |
Ø100mm |
100 mm convex/ 150mm concave |
7.0mm |
Ni50M |
2mils |
Electroplated Nickel on Non-Ferrous |
±(1μm+5% of reading) |
Ø15mm |
5 mm convex/ 25mm concave |
- |
Ni100M |
4 mils |
Electroplated Nickel on Non-Ferrous |
±(1μm+5% of reading) |
Ø15mm |
5 mm convex/ 25mm concave |
- |
NiFe50M |
2mils |
Electroplated Nickel on Steel |
±(2μm+8% of reading) |
Ø20mm |
10 mm convex/ 25mm concave |
0.5mm |
Ambient Temperature |
-20°C-100°C |
Conforming Standards |
DIN EN ISO 2178, DIN 50 982, ASTM B 499, E 376, D 1186, G 12, B 530, BS 5411, ISO 2361 |
Dimensions |
Gauge: 215mmx55mmx29mm Plastic carrying case: 235mmx185mmx46mm |
Weight |
Case incl. gauge approx. 560g |
Calibration Shims |
Here are the two technical reasons why you cannot use plastic shims/foils plus zero plate to check calibration of MikroTest: |