TM-12E AC Clamp Meter1.CAT III 600V
2.3-3/4 digit LCD with Analog Bargraph.
3.Display Counts: 4000.
4.Auto Ranging.
5.Auto power off. (after 30 minutes).
6.High speed bargraph.
7.Data Hold and Range Hold keys.
TM-13E AC/DC Clamp Meter1.CAT III 600V.
2.3-3/4 digit LCD with Analog Bargraph.
3.Display Counts: 4000.
4.Low battery indication.
5.Auto Ranging.
6.Data Hold and Range Hold Auto Zero.
7.Test Ranges: ACV, ACA, DCV,
TM-14E AC/DC Current Transducer1.CAT III 600V
2.AC/DC current ranges 40A and 400A.
3.Maximum conductor size 30mm.
4.Low battery indication.
TM-15E AC Current Transducer1.CAT III 600V
2.AC current range 400A
3.Maximum conductor size 30mm
TM-16E AC Clamp Meter1.CAT III 600V
2.3-1/2 digit LCD with maximum reading of 2000.
3.Data Hold.
4.AC volts, DC volts, AC current, Resistance, Continuity, Diode ranges.
5.Autoranging.
6.Maximum conductor size 30m
TM-24E AC/DC Clamp Meter1.CAT III 600V
2.3-1/2 digits LCD, Backlit Display with maximum reading of 2000.
3.Data Hold, Max Hold.
4.ACV, ACA, DCV, DCA, Resistance, Frequency, Diode and Continuity buzzer.
5.Maximum conduc
TM-28E TRMS AC/DC WATT Clamp Meter1.CAT III 600V
2.3-3/4 digit LCD, Backlit Display with maximum reading of 4000.
3.High-speed bargraph.
4.True-Rms.
5.Watt measurement: 400KW
6.Data Hold, Peak Hold, Min/Max, and Zero function
TM-1004 100A-AC/DC Current Transducer1.CAT III 600V
2.AC/DC current ranges 10A and 100A.
3.Maximum conductor size 30mm.
4.Low battery indication.
TM-1014 AC Clamp Meter1.CAT III 600V
2.3-3/4 digit LCD Backlit Display, with Analog Bargraph.
3.Display Counts: 4000.
4.Auto Ranging.
5.Data Hold and Min/Max functions.
6.Test Ranges: ACV, ACA, DCV, Resistance, Fr
TM-1016 AC-HVAC Clamp Meter1.CAT III 600V
2.3-3/4 digit LCD Backlit Display, with Analog Bargraph.
3.Display Counts: 4000.
4.Auto Ranging.
5.AC/DC current: 0.1µA to 4000µA. (using test leads).
6.AC current: 0.01A to 40
TM-1017 400A True-RMS AC Power Clamp Meter + Phase Rotation1.CAT III 600V
2.Maximum conductor size 30mm.
3.Display counts: 4000.
4.Measures: ACV, DCV, ACA.
5.Measures Phase Sequence.
6.Voltage/Current Harmonics to 25th with THD.
7.W3ø, HV, HA, Phas
TM-2011 AC Clamp Meter1.CAT IV 600V, CAT III 1000V
2.3-3/4 digit LCD backlit display and bargraph, with maximum reading of 4000.
3.AC voltage range: 0 to 750V.
4.AC current range: 0 to 660A.
5.DC voltage range: 0 to
TM-2013 TRMS AC/DC Clamp meter1.CAT IV 600V, CAT III 1000V
2.LCD backlit display, with maximum reading of 6600.
3.AC voltage range: 0 to 750V.
4.AC current range: 0 to 660A.
5.DC voltage range: 0 to 1000V.
6.DC Current: 0
TM-3011 AC Clamp Meter1.CAT IV 600V, CAT III 1000V
2.3-3/4 digit LCD Backlit display with maximum reading of 4000.
3.Analog Bargraph.
4.AC voltage range: 0 to 750V.
5.AC current range: 0 to 1200A.
6.Peak Hold, Dat
TM-3013 AC/DC Clamp Meter1.CAT IV 600V, CAT III 1000V
2.3-3/4 digit LCD Backlit display with maximum reading of 4000.
3.Analog Bargraph.
4.AC voltage range: 0 to 750V.
5.AC current range: 0 to 1200A.
6.DC voltage ran
TM-3014 AC/DC Clamp Meter1.CAT IV 600V, CAT III 1000V
2.LCD Backlit display with maximum reading of 6600.
3.AC voltage range: 0 to 750V.
4.AC current range: 0 to 1200A.
5.DC voltage range: 0 to 1000V.
6.DC current ra
YF-800 AC Analog Clamp Meter1.Rotary scale presents one range at a time..
2.Function Key: Pointer lock switch.
3.AC Voltage Ranges: 150V, 300V, 600V.
4.AC Current Ranges: 6A, 15A, 60A, 150A, 300A.
5.Resistance.
6.Max.
YF-8020 AC Clamp Meter1.3-1/2 digit LCD with maximum reading of 2000.
2.AC voltage range: 200V, 750V.
3.AC current range: 20A, 200A, 600A.
4.Resistance measurement to 2000 ohms.
YF-8030A AC/DC Clamp Meter1.CAT III 1000V
2.3-3/4 digit LCD with maximum reading of 4000.
3.Overload indication.
4.Automatic polarity.
5.Low battery indication.
6.AC voltage range: 0 to 750V.
7.AC current range: 0 t
YF-8050 AC Clamp Meter1.CAT III 1000V
2.3-3/4 digit LCD display with maximum reading of 4000.
3.Overload indication.
4.Low battery indication.
5.AC voltage range: 0 to 750V.
6.AC current range: 0 to 1000A.
7.Pea
YF-8070 AC Clamp Meter1.CAT II 600V
2.3-1/2 digit LCD with maximum reading of 2000.
3.AC voltage range: 200V, 750V.
4.AC current range: 20A, 200A, 600A.
5.Resistance measurement to 2000 ohms.
6.Data Hold, Peak Hol
YF-8160 100A Leakage AC Clamp Meter1.CAT III 600V.
2.Maximum conductor size : 30mm.
3.Display counts : 4,000.
4.Test ranges: ACV (600V), ACA (100A), Ohm, Continuity.
5.Leakage Current Test.
TM-71 Pen Type Pocket Multimeter1.CAT IV 600V
2.LCD display with maximum reading of 4000, plus decimal point.
3.Analog Bargraph.
4.AC voltage range: 0 to 600V.
5.DC voltage range: 0 to 600V.
6.Auto power off (15 minutes).
TM-72 Pen Type Pocket Multimeter + Phase Rotation Tester1.CAT IV 600V
2.LCD display with maximum reading of 6000, plus decimal point.
3.Analog Bargraph.
4.AC voltage range: 0 to 600V.
5.DC voltage range: 0 to 600V.
6.Auto power off (15 minutes).
TM-81 Digital Multimeter1.CAT IV 600V
2.LCD display with maximum reading of 1999
3.AC voltage range: 0 to 600V.
4.DC voltage range: 0 to 600V.
5.Auto power off (15 minutes).
6.ACV, DCV, Resistance, Diode, Continuity
TM-82 Digital Multimeter1.CAT IV 600V
2.LCD Backlit Display, with maximum reading of 1999
3.AC voltage range: 0 to 600V.
4.DC voltage range: 0 to 600V.
5.Auto power off (15 minutes).
6.ACV, DCV, Resistance, Diode, C
TM-86 Digital Multimeter1.CAT IV 600V
2.LCD Backlit Display, with maximum reading of 3999
3.AC voltage range: 0 to 600V.
4.DC voltage range: 0 to 600V.
5.AC Current range: 0.1A to 10A.
6.DC Current range: 0.1A to 10
TM-87 Digital Multimeter1.CAT IV 600V
2.LCD Backlit Display, with maximum reading of 3999.
3.Analog Bargraph Display
4.True Rms.
5.AC voltage range: 0 to 1000V.
6.DC voltage range: 0 to 1000V.
7.AC Current range:
TM-88 Digital Multimeter1.CAT IV 600V
2.LCD Backlit Display, with maximum reading of 3999.
3.Analog Bargraph Display
4.True Rms.
5.AC voltage range: 0 to 1000V.
6.DC voltage range: 0 to 1000V.
7.AC Current range:
DC Holiday DetectorHigh Voltage Direct Current DC Holiday Detector. Measuring Ranges:Model DC15: 0 to 15,000 Volts, Model DC30: 0 to 30,000 Volts.
High Voltage DC Crest MeterHigh Voltage DC Crest Meter. Measuring Ranges: 0 to 30,000 volts.
EBE External Rolling Pipeline BrushesExternal Rolling Pipeline Brushes. Available in diameters of 1" (25mm) to 20" (508mm).
PHD Wet Sponge Pin Hole DetectorWet Sponge Pin Hole Detector. Measuring Ranges: 0 to 20 mils (0 to 500 µm).
PoroTest-7 High Voltage Porosity Holiday DetectorPoroTest 7 High Voltage Porosity Holiday Detector, designed for detecting flaws and pores (holidays).
PosiTest-LPD Low voltage Pinhole DetectorThe PosiTest LPD Low voltage Pinhole Detector detects holidays, pinholes and other discontinuities on metal and concrete substrates.
PU-CREST High Voltage Pulse Crest MeterHigh Voltage Pulse Crest Meter. Measuring Ranges: 5,000 to 30,000 volts.
High Voltage Pulse Holiday DetectorHigh Voltage Pulse Holiday Detector. Measuring Ranges: Model P20: 2,000 to 20,000 Volts;Model P40: 5,000 to 40,000 Volts;Model P60: 10,000 to 60,000 Volts.